Performance
Data ALLMAG CMIT
|
Capacity
|
Q
|
up to
|
80
|
m³/h
|
|
Delivery head
|
H
|
up to
|
55
|
m
|
|
Discharge pressure
|
pd
|
up to
|
16
|
bar
|
|
Fluid
temperature
|
t
|
up to
|
207/350
|
°C
|
Construction
features
Rated
output acc. DIN EN 22858/ISO 2858
Technical
execution acc. DIN EN ISO 5199/ISO 5199
Block
design (Motor attached to pump via flange or lantern)
In-line
design (suction and discharge branch in-line arranged)
Dry
installation
Vertical
installation
Horizontal
installation
Stub
shaft für IEC motor
With
magnetic drive